Saturday 3 February 2018

Boiler Plus Legislation

We have a change to the Building Regulations coming up in April 2018 see here for the full details HEAT IN BUILDINGS, Boiler Plus from the Department for Business, Energy & Industrial Strategy.

So is this some huge radical shake up that will change our industry, in my opinion, NO, in fact to me they are well behind the real industry of installers at the coal face who have already been doing what they are proposing for years, so in fact as far as I am concerned, this Legislation is just trying to catch up with what the good installers already do.

What is the new Legislation calling for, well in simple terms it is saying when you install a combination boiler you must either add one of the following to the system to add more to the efficiency.

1. Flue Gas Heat recovery system
2. Weather Compensation
3. Load Compensation
4. Smart Controls With Automation and Optimisation functions

Many, many installers around the UK have already been doing this for a number of years, it is these installers who are leading the industry and it seems those who make the Legislation are playing catch up, surely it should be the other way round.

Yet again, those who make the Legislation are missing the bigger picture same as the ErP missed the bigger picture, its all well and good fitting a new boiler and adding additional components to supposedly acheive higher efficiency, but the missing fact is insulation, if the property is poorly insulated, then all the expense of new boiler and expensive controls is partially wasted by the additional heat loss due to poor insulation, is it not time we worked together with insulation businesses and double glazing businesses to ensure the customer took the best option to save them energy, which in my opinion will not always be change the boiler, sometimes it would be better and cheaper to improve the insulation to reduce heat loss and so reduce bills.

The other fact I am really struggling to get my head round and so far I have not found anyone who can answer this yet, is this new Legislation, of additional controls to improve efficiency is only for Combination boilers, what about system boilers and heat only boilers, OK I understand that Flue Gas Heat Recovery is only for combination boilers hot water production, but the other controls, will work just as well on these boilers and I know most installers including myself already fit these controls with these boilers, but why have the Department for Business, Energy & Industrial Strategy missed these off for system and regular boilers, if you look at the chart below from HHIC it shows a simplified graph for the new Legislation



Now as you can see, when you start it asks the question, Is it a combi? if you answer No, it then asks, Does it have a timer and Thermostat? if you answer YES, then it says, No Additional Components required, if you answer NO, then it says Central Heating Timer and Thermostat to be installed with the boiler, Really, this is supposed to be progress, so with a system boiler or regular boiler, we can just fit old fashioned ON/OFF controls, no weather compensation, no load compensation, no smart controls required, WHY are these boilers allowed to be installed without good modern controls, do they think we all fit Combination boilers, (a boiler often used for convenience, not because it the best solution) well we don't, can someone please explain to me why this has been missed.

The final point I would like to raise, is how will this be policed, will it become part of the Notification procedure, or will it be as usual, just bring in the legislation, let those who always abide by the regulations comply, but ignore those who just don't care and always ignore everything, as they know, nothing will be done

3 Comments:

At 3 February 2018 at 09:39 , Blogger Mike Walton said...

Chris,this will not be policed, just like Part L, ERP and Benchmark. Just box ticking exercises for politicians. While there are a few of us who are up to date and fit the latest modulating controls, the vast majority of installers stick to what they have been doing for the last 40 years. I still come across fairly new installations with no roomstat. Often the Benchmark is either not filled in or the figures are just copied from the MIs.

 
At 3 February 2018 at 10:47 , Blogger Kingston Gas Services Ltd said...

This will only make the price gap between poor installers and the ones who do the job right, the installer who supplies and fits a combi for £1000 will not do this, he gets paid cash and doesn’t fill out any paperwork, more should be done to stop this first. The reputable installers will be the ones loosing out again

 
At 5 February 2018 at 08:27 , Anonymous Pdm plumbing and heating said...

I agree regards insulation. There are so many properties around Stockport that have little or no insulation in roof spaces, suspended floors. Even on refurbishment jobs upgrading the insulation is mostly overlooked as an unnecessary expense. Well fitted window,doors and insulation is a must.

 

Post a Comment

Subscribe to Post Comments [Atom]

<< Home